The Mechanism
While RAID 6 beautifully solves the vulnerability that kills RAID 5 arrays (failing during a rebuild), it is still bound by mathematical limits. If one or two drives fail, the array enters a "Degraded" state. To restore redundancy, the failed drives must be replaced, triggering an Array Rebuild.
Because RAID 6 arrays typically consist of high-capacity enterprise drives (e.g., 12TB to 24TB+), a rebuild requires reading petabytes of data across the remaining drives. This process can take days or even weeks.
The Impact on RAID 6
If the array is already running degraded with two missing/failed drives, the remaining healthy drives are subjected to massive, non-stop read stress. If a third drive suffers a mechanical head crash, an electrical short, or a total controller failure before the rebuild finishes, the array surpasses its fault tolerance limit. The entire RAID 6 volume collapses instantly, resulting in catastrophic data loss.